Quarry Road substation detailed design. The substation development will include a 33 kV switchboard, one 33/11 kV 5 MVA transformer and an 11 kV switchboard. The site will be designed to accommodate a second supply transformer. The design for this substation was substantially completed, and the project was put on hold. The bulk of the civil and structural design, as well as the primary design, is expected to be used as far as practicable. Tenderers should be aware that PowerNet’s secondary and protection design requirements have undergone significant changes since the previous design was completed. The substation design includes the following: • Bus the Halfway Bus-Palmerston 1 and 2 feeders at Quarry Road • One 33 kV/11 kV, 3.5/5 MVA ONAN/ONAF, OLTC transformer • Relocation of the ripple control from TPT Palmerston 110/33 • 33 kV and 11 kV points of connection for the mobile substation • Substation civil works, including site grading, fencing and earth grid • Communications mast • New switch room • New 11 kV Feeder cabling • Protection System • Scada System • Safety in Design Reviews • Procurement Assistance • Construction Package
Termin
28.10.2025
Opublikowano
12.11.2025
Udzielone
12.11.2025
Registration of Interest (ROI) - PowerNet Distribution Network Services - Lakeland Network
Zamknięte·Aug 4
RFT - 220kV EDN GXP and 100kV Line Build Project | CIVILS
Udzielone·May 29
Construction and Installation Services for Kelso and Waikaka Transformer Replacements.
Udzielone·Dec 8
Main Contractor for the new PowerNet Frankton Depot
Udzielone·Dec 3
Advance Notice - RFT SPF Package 10A - Electrical Integration Contractor
Przyjmowanie ofert·Sep 29
Registration of Interest (ROI) - PowerNet Distribution Network Services - Lakeland Network
Zamknięte·Aug 4
RFP - Watercare Electricity Supply
Zamknięte·Jul 20
P2026-777 2026 Street Light and Traffic Signal Management Contract
Udzielone·May 6
Request for Proposal (RFP) Electricity Supply
Udzielone·Apr 20
Health NZ Te Toka Tumai Auckland - Greenlane Clinical Centre Electrical HV Works - 2 x Prefabricated Substation Switchrooms
Udzielone·Oct 5
Playground Upgrade at Sandspit Road School
Przyjmowanie ofert·Oct 27
TKKM o Kawakawa mai Tawhiti - Gym Floor Replacement - Main Contractor Services
Przyjmowanie ofert·Oct 27
Cannons Creek Cage Renewal
Przyjmowanie ofert·Oct 27
Contract 26-76 - Rural Intersection Flag Lighting - Request for Proposal – Advertising Notice
Przyjmowanie ofert·Oct 27
ROI - Future Waste Pathways
Przyjmowanie ofert·Oct 27
Advance Notice | New Dunedin Hospital Inpatients Medium Temperature Hot Water Heat Pumps
Przyjmowanie ofert·Oct 27
Utwórz konto, aby przeanalizować to zamówienie i znaleźć podobne możliwości.