Quarry Road substation detailed design. The substation development will include a 33 kV switchboard, one 33/11 kV 5 MVA transformer and an 11 kV switchboard. The site will be designed to accommodate a second supply transformer. The design for this substation was substantially completed, and the project was put on hold. The bulk of the civil and structural design, as well as the primary design, is expected to be used as far as practicable. Tenderers should be aware that PowerNet’s secondary and protection design requirements have undergone significant changes since the previous design was completed. The substation design includes the following: • Bus the Halfway Bus-Palmerston 1 and 2 feeders at Quarry Road • One 33 kV/11 kV, 3.5/5 MVA ONAN/ONAF, OLTC transformer • Relocation of the ripple control from TPT Palmerston 110/33 • 33 kV and 11 kV points of connection for the mobile substation • Substation civil works, including site grading, fencing and earth grid • Communications mast • New switch room • New 11 kV Feeder cabling • Protection System • Scada System • Safety in Design Reviews • Procurement Assistance • Construction Package
Date limite
28.10.2025
Publié
12.11.2025
Attribué
12.11.2025
Registration of Interest (ROI) - PowerNet Distribution Network Services - Lakeland Network
Clôturé·Aug 4
RFT - 220kV EDN GXP and 100kV Line Build Project | CIVILS
Attribué·May 29
Construction and Installation Services for Kelso and Waikaka Transformer Replacements.
Attribué·Dec 8
Main Contractor for the new PowerNet Frankton Depot
Attribué·Dec 3
Advance Notice - RFT SPF Package 10A - Electrical Integration Contractor
Ouvert aux offres·Sep 29
Registration of Interest (ROI) - PowerNet Distribution Network Services - Lakeland Network
Clôturé·Aug 4
RFP - Watercare Electricity Supply
Clôturé·Jul 20
P2026-777 2026 Street Light and Traffic Signal Management Contract
Attribué·May 6
Request for Proposal (RFP) Electricity Supply
Attribué·Apr 20
Health NZ Te Toka Tumai Auckland - Greenlane Clinical Centre Electrical HV Works - 2 x Prefabricated Substation Switchrooms
Attribué·Oct 5
Main Contractor for Block E (Music Suite) Roof & Wall Recladding at Maruawai College
Ouvert aux offres·Nov 1
Main Contractor for Roofing Refurbishment at Avalon School (Wellington)
Ouvert aux offres·Nov 1
Notice of Information - Napier City Council Tender Dates Over Holiday Season
Ouvert aux offres·Nov 1
Howick Fire Station
Ouvert aux offres·Nov 1
SCI_2600812 High Stage Rating Curve Modelling
Ouvert aux offres·Nov 1
Kelburn Viaduct Safety Screens
Ouvert aux offres·Nov 1
Créez un compte pour étudier cet appel d’offres et trouver des opportunités similaires.