253 Plus employs a 10 kV acceleration voltage electron-impact ionization source which provides exceptional ion transmission and sensitivity while supporting the stringent linearity required for high-precision isotope ratio measurements. 253 Plus provides optimized sensitivity and linearity operating modes, including: Sensitivity Mode: 600 molecules/ion Linearity Mode: 900 molecules/ion, with linearity of 0.02 ‰/nA This is central to applications requiring the highest level of isotope-ratio performance. The 253 Plus ion-source housing is machined from a single piece of metal not welded components. This minimizes surfaces capable of retaining adsorbed water. Materials that can contribute to memory effects through chemisorption are similarly minimized and replaced by inert materials. This design is particularly important in high-precision IRMS because residual water can contribute to memory and non-linearity. Internal radiant heating and monoblock source architecture provides a highly controlled source environment for demanding stable-isotope measurements. The 253 Plus incorporates VISC, which can be adjusted externally without opening the vacuum system. The 253 Plus ion source is mechanically self-aligning and can only be installed in the correct orientation. The filament is designed as a plug-in module with simplified installation and minimal possibility of incorrect positioning. This reduce maintenance time and minimize the possibility of changes in source alignment following routine maintenance. The 253 Plus platform is differentiated by intellectual property relating to high-performance isotope-ratio detection and dynamic-range enhancement. Transimpedance amplifier technology – Heinz Lerche: UK Pat. GB2526857B USA Pat. US9431976B2 China Pat. CN105305976B Dynamic Range Improvement for Isotope Ratio Mass Spectrometry – Andreas Hilkert, Anne Trinquier, Jens Radke and Johannes Schwieters: USA Pat. US10312071B2 UK Pat. GB2541385B
Zveřejněno
23.10.2026
Přiděleno
23.10.2026
A Element Analyzer Isotope Ratio Mass Spetrometer,10 kV 253 Plus IRMS architecture
Přiděleno·Nov 5
Scalable Platform for Long-Term Functional Monitoring and Characterization of Engineered Muscle Tissues
Otevřeno k podání nabídek·Oct 29
Forhåndsmeddelelse om kommende udbud af rammeaftaler mhp. levering af laboratoriehandsker til danske universiteter,
Plánování·Oct 23
The supply of a SMARTLab SE multipurpose diffractometer
Přiděleno·Oct 19
Analyseudstyr til massespektrometri. Analyse af biologiske prøver samt narko-effekter for lægemiddel- og misbrugsstoffer
Přiděleno·Oct 15
2 pipetteringsrobotter til udvidelse af eksisterende produktionskapacitet
Přiděleno·Oct 9
ICP-MS/MS system for elemental analysis of high-salinity brines
Přiděleno·Nov 5
A Element Analyzer Isotope Ratio Mass Spetrometer,10 kV 253 Plus IRMS architecture
Přiděleno·Nov 5
Procurement of Biomark X9 system
Přiděleno·Oct 30
Analyseudstyr til massespektrometri. Analyse af biologiske prøver samt narko-effekter for lægemiddel- og misbrugsstoffer
Přiděleno·Oct 15
Orbital Tribrid APEX og Orbitrap Astral Zoom
Přiděleno·Sep 30
Triple quadrupole liquid chromatography-mass spectrometry (LC-MS/MS)
Uzavřeno·Sep 25
Procurement of monoflange valves for Køge, Herning and Frøslev - 26/12038
Přiděleno·Nov 5
GENOP-BR Renovering af brolægning på fortove (Indgået kontrakt GENOP-BR.310.14)
Přiděleno·Nov 5
- Hovedentreprise
Otevřeno k podání nabídek·Nov 5
ICP-MS/MS system for elemental analysis of high-salinity brines
Přiděleno·Nov 5
Midlertidige pavilloner anvendt til udslusningspladser
Otevřeno k podání nabídek·Nov 5
Udbud af helhedspleje
Přiděleno·Nov 5
Vytvořte si účet, prozkoumejte tuto zakázku a najděte podobné příležitosti.